Product Type:Multifunction Battery Tester
Product Model:PZEM-013/015
Product Function:
This document describes the specification of the PZEM-013/015 DC multifunction battery tester, this meter is mainly used to test all kinds of battery’s voltage、discharge current、discharge power、discharge impedance、internal resistance、capacity、SOC、energy、 running time, and display the measurement data through LCD screen.
PZEM-013: Measuring Range 10A (Built-in Shunt)
PZEM-015: Measuring Range 300A (use external shunt, can matched with 50A, 100A, 200A, 300A four kinds of shunt).
Measurement range:
Voltage
Measuring range: 0-200V. (when the test voltage is <8V, please use the independent power supply mode)
Minimum resolution:0.01V
The starting test voltage: 0.05V
Measurement accuracy:1%
Current
Measuring range: 0-10A. (Type: PZEM-013)
0-300A(Type: PZEM-015) can set 50A, 100A, 200A,300A four range depend on the external shunt, the factory default is 100A.
Minimum resolution: 1mA
The starting test current: 10mA(Type: PZEM-013)
20mA(Type: PZEM-015)
Measurement accuracy:1%
Power
Measuring range: 0-2000W (Type: PZEM-013)
0-60000W(Type: PZEM-015).
Minimum resolution: 0.01W
The starting test power: 0.1W (Type: PZEM-013)
0.2W (Type: PZEM-015)
Measurement accuracy:1%
Impedance
Impedance=Voltage/ Current
Measuring range: 0-1000Ω
When over the test range or the current is zero, it display “---”
Minimum resolution: 0.1Ω
Measurement accuracy:1%
Internal Resistance
Internal resistance= (Full voltage – Bring load voltage) / Bring load current, when the bring load voltage is larger than the maximum voltage, the internal resistance is zero.
Measuring range: 0-999mΩ
Display format: 999mΩ, when over the test range or the current is zero, it display “---”.
Minimum resolution: 1mΩ
Measurement accuracy:1%
Note: Before you test the internal resistance, you should preset the full voltage depend on the battery type, after it is fully charged you can use it to test; if you do not fully charge it, you can set the battery without load voltage is the full voltage, then test; the internal resistance is not a fixed value, the more the battery discharged, the bigger the resistance.
Capacity
Measuring range: 0-1000AH
Minimum resolution: 1mAH
Measurement accuracy:1%
Note: Battery capacity testing is a cumulative process of discharge current versus time, it need some time, the time is depend on the discharge current; before you test the capacity, you should preset the full voltage and the cut-off voltage depend on the battery type, after it is fully charged you can use it to the discharge test; When the dump energy display blank, it means the discharge is over, this capacity display value is the battery’s capacity.
SOC
SOC is display via the battery symbol, totally 10 grids, every grid present 10% energy.
SOC is calculated via the current battery voltage value, before test you should preset the full voltage and the cut-off voltage depend on the battery type; every grid voltage = (the highest voltage – the lowest voltage) / 10.
Energy
Measuring range: 0~9999kWh
Over the test range will become zero.
Minimum resolution: 1Wh
Measurement accuracy:1%
Note: 1Wh=0.001kWh=0.001 Kilowatt
Running time
Measuring range: 0 ~ 999 hour (without load the time will not accumulate)
Over the test range will become zero.
Product picture:
Contact number:86-0574 88466521
Email:manager@peacefair.cn
Fax:86-0574 88466891
Address:No. 962, Mingshu Road, Jiangshan Town, Yinzhou District, Ningbo City, Zhejiang Province