Product Type:DC Digital Multi-function Meter
Product Model:PZEM-031
Product Function:
1. Electrical parameter measurement function (voltage, current, active power, energy)
2. Voltage alarm function (over voltage alarm threshold, backlight and voltage flashing to alarm).
3. The reset function of energy key.
4. Store data when power off.
5. Large-screen LCD (display voltage, current, active power, energy at the same time)
6. Backlight function.
Measurement range:
1.Power: test range: 0~2kW
Within 1KW, the display format is 0.0~999.9W;
1KW and above, the display format is 1000~2000W.
2.Energy: test range: 0~9999kWh
Within 10KWh, the display format is 0~9999Wh;
10kWh and above, the display format is 10~9999kWh.
3.Voltage: test range: 6.5~100V
Display format: 6.50~99.99V
4.Current: test range: 0~20A
Display format: 0.00~20.00
Product picture:
Product Type | PZEM-031 |
Current Range | 0-20A(Don't need external shunt) |
Voltage Range | AC 6.5-100V |
Function
| 1. Measure voltage, current, active power, energy 2. Voltage alarm function 3. Reset energy 4. Store data when power off. 5. Large-screen LCD 6. Backlight function.
|
Power Range | 0~2kW |
Energy Range | 0~9999kWh |






1. Power: test range: 0~2kW
Within 1KW, the display format is 0.0~999.9W;
1KW and above, the display format is 1000~2000W.
2. Energy: test range: 0~9999kWh
Within 10KWh, the display format is 0~9999Wh;
10kWh and above, the display format is 10~9999kWh.
3. Voltage: test range: 6.5~100V
Display format: 6.50~99.99V
4. Current: test range: 0~20A
Display format: 0.00~20.00



Reset energy
Step1: Long press the key until the power display area display “CLr”, then release the key.
Step2: At this moment, the energy is flashing to prompt this is the energy reset state, if short press the key again, then the
energy value is cleared and exit the reset flashing state.
Step 3: If there is no operation within 5 seconds, it means the energy value is not cleared and will exit the reset state.
Set voltage alarm threshold
Step1: Long press the key until the power display area display “SET”, then release the key.
Step2: After enter this state, the voltage area display the current high voltage alarm value, the current area display the current
low voltage alarm value and the last digit begin to flash, then you can short press to plus 1, when there is no operation over 3 seconds, it will switch the digit position automatically, from the high voltage alarm value to the low voltage alarm value, there are total six digits, the range of the voltage alarm threshold is 6.5~99.9V;
Step3: After finish the setting, long press the key until the screen display “PASS”, that means you set successfully and will exit the setting state automatically.